T2310 DC 12V 24V AC 110V 220V Programmable Digital Time Delay Switch Relay 1.37 Inch LCD Digital Display Time Controller Module
Products Description
Product Features.
T2310 is a time control relay, equipped with a 1-way normally open type relay
According to the different working voltage is divided into DC12V, DC24V and ACA110~220V three specifications
Fixed bit on and off timing display settings, independent timing units, enabling large time span start/stop
Optimized setting operation, more convenient and intuitive for setting timer on, timer off and infinite cycle switch
1~999 times alternate work and infinite cycle work independent settings, to maximize the use of demand
Basic parameters.
Working voltage: DC12V, DC24V, AC110~220V
Load power: 240W, 480W, 2200W (subject to the label load power)
Timing range: 0 ~ 999 (seconds, minutes, hours)
Minimum unit: 1 second Error: 20ppn
Timing type: non-clock type countdown
Timer on: support
Timer shutdown: support
Infinite cycle: support infinite on/off cycle
Quantitative cycle: support 1~999 times cycle switch
Shell material: ABS
Independent timing unit: support
Program trigger: support automatic trigger and manual trigger switch, factory default automatic trigger
Setting lock: support
Power-down saving: only the last setting is automatically saved
Relay type: 1 way normally open relay
Output type: contact with power, active output
Product size: 67×45×34mm
Installation opening size: 63 × 42mm (embedded installation)
Operating voltage = input voltage = output voltage = label label voltage
Operation introduction:
1. In the conventional interface, long press the SET button for 10 seconds to enter the setting mode, the red digital tube displays the code, and the green digital tube displays the code parameter value; press the SET key to switch the code, and press the up/down keys to modify the parameter value.
2. Adjust the value of P0 and P1 to 0 (time unit is second)
3. Adjust P2 to 5, the relay is closed first and then opened, and continuously circulates
4. Wait for 10 seconds to automatically save the settings after the code setting is completed
5. To set the timing time, double-click the SET button on the conventional interface, the red digital tube flashes, press the up/down keys to adjust the value to 10, click the SET button, the green digital tube flashes, adjust the value to 50, wait for 10 seconds to automatically save, set carry out.
All settings are automatically saved when power is turned off and run automatically when power is turned on, without manual start.
Press and hold the SET key to power on to restore the factory settings.
Feature:
Independent crystal oscillator, more accurate timing
1. Convenient direct output wiring
2. Add buzzer and audible alarm
3. Add pause button to stop urgently
5. Start and stop setting mode, provincial conversion, which is more convenient
6. Automatically save when power off, run automatically when power on
7. Timing units can be set separately, with 36 working combinations
8. Timing range: 0-999 seconds, minutes, hours.
9. To count in minutes or hours, the digital tube flashes in seconds.
Note: This product is a countdown operation and cannot be set to a 24-hour working mode.